A new measurement of the neutron detection efficiency for the NaI Crystal Ball detector

Show simple item record

dc.creator Martemianov, M.
dc.creator Kulikov, V.
dc.creator Demissie, B. T.
dc.creator Marinides, Z.
dc.creator Akondi, C. S.
dc.creator Annand, J. R. M.
dc.creator Arends, H. J.
dc.creator Beck, R.
dc.creator Borisov, N.
dc.creator Braghieri, A.
dc.creator Collicott, Cristina
dc.creator Sarty, Adam James, 1965-
dc.date.accessioned 2017-05-01T12:21:10Z
dc.date.available 2017-05-01T12:21:10Z
dc.date.issued 2015-04-07
dc.identifier.issn 1748-0221
dc.identifier.uri http://library2.smu.ca/handle/01/26911
dc.description Pre-print en_CA
dc.description.abstract We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball detector obtained from a study of single [pi][superscript 0] photoproduction on deuterium using the tagged photon beam at the Mainz Microtron. The results were obtained up to a neutron energy of 400 MeV. They are compared to previous measurements made more than 15 years ago at the pion beam at the BNL AGS. en_CA
dc.description.provenance Submitted by Janine Mills (janine.mills@smu.ca) on 2017-05-01T12:21:10Z No. of bitstreams: 1 Collicott_Cristina_article_2015.pdf: 193537 bytes, checksum: 0d7fc6aed5f44a5c4017dd7096f456c1 (MD5) en
dc.description.provenance Made available in DSpace on 2017-05-01T12:21:10Z (GMT). No. of bitstreams: 1 Collicott_Cristina_article_2015.pdf: 193537 bytes, checksum: 0d7fc6aed5f44a5c4017dd7096f456c1 (MD5) Previous issue date: 2015-02-25 en
dc.language.iso en en_CA
dc.publisher IOP Publishing en_CA
dc.relation.uri http://dx.doi.org/10.1088/1748-0221/10/04/T04001
dc.rights This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/1748-0221/10/04/T04001.
dc.subject.lcsh Neutron counters -- Evaluation
dc.subject.lcsh Particles (Nuclear physics)
dc.subject.lcsh Calorimeters
dc.title A new measurement of the neutron detection efficiency for the NaI Crystal Ball detector en_CA
dc.type Text en_CA
dcterms.bibliographicCitation Journal of instrumentation 10, T04001. (2015) en_CA
 Find Full text

Files in this item


 

Copyright statement:

 
This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/1748-0221/10/04/T04001.
 
Published Version: http://dx.doi.org/10.1088/1748-0221/10/04/T04001
 
 

This item appears in the following Collection(s)